The underside of a range's control panel tipped forward with its cover off, a flat ribbon cable running from the display to the main board.

Thermador induction range
showing E9000

Thermador uses E9000 and E9010 when the voltage reaching the induction range is outside its normal operating range.

(844) 875-7576

Mon–Sat, 8am–8pm

  • Controls and communication
  • Knobs, switches and controls
  • Source: Thermador

Book a visit

Three short steps, about a minute.

or call (844) 875-7576

Before you book,
in this order.

Each step comes from Thermador's own guidance for E9000 on its ranges. Follow it to the end: the last card says whether this is a visit.

01

Switch the range off at the breaker.

02

Have the supply checked by your utility or an electrician; book a visit if it is normal.

Still there?

It usually turns into knobs, switches and controls. Book with the code and the model number.

What not to do

These codes do not concern pans or zones.

What you may
notice with it.

The range problems E9000 tends to arrive with. Answer these at the range before anyone is booked.

All problems

Where E9000 usually leads

Knobs, switches and controls.

Knobs, keypad or control board · moderate.

In Thermador's own words

The supply voltage is incorrect. It is outside the normal operating range.
Thermador "Ranges - Error Codes" support page

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Only Thermador's induction models show E9000; the gas and dual-fuel ranges do not have an induction top.

Thermador E9000 range repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A parent and a child stirring a pot on a gas range together in a bright kitchen
For the heart of your home.

Questions
about E9000.

Can I clear E9000 myself?
Switch the range off at the breaker. If it comes back, it needs a visit.
Is E9000 on my Thermador a problem with the range itself?
Thermador ties it to the supply voltage. The circuit is checked first.
What should I tell the electrician about E9010 on my Thermador?
That the range reports a supply voltage outside its normal range, so the voltage at the range should be measured.

Back to your everyday

Still showing E9000?

Book with the code exactly as it appears, the full model number, and whether you notice any smell of gas or scorching — with a code, that is where the diagnosis begins.

(844) 875-7576 Schedule a repair